Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Soc Echocardiogr ; 32(5): 655-666.e13, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30826226

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is a significant contributor to morbidity and mortality in patients with hypoplastic left heart syndrome. The goal of this study was to characterize the dynamic annular motion of the tricuspid valve in patients with HLHS with a Fontan circulation and assess the relation to tricuspid valve function. METHODS: Tricuspid annuli of 48 patients with HLHS with a Fontan circulation were modeled at end-diastole, mid-systole, end-systole, and mid-diastole using transthoracic three-dimensional echocardiography and custom code in 3D Slicer. The angle of the anterior papillary muscle (APM) relative to the annular plane in each systolic phase was also measured. RESULTS: Imaging was performed 5.0 years (interquartile range, 2-11 years) after Fontan operation. The tricuspid annulus varies in shape significantly throughout the cardiac cycle, changing in sphericity (P < .001) but not in annular height or bending angle. In univariate modeling, patients with significant TR had larger changes in septolateral diameter, lateral quadrant area, and posterior quadrant area (P < .05 for all) as well as lower (more laterally directed) APM angles (P < .001) than patients with mild or less TR. In multivariate modeling, a 1 mm/(body surface area)0.5 increase in the maximum change in septolateral diameter was associated with a 1.7-fold increase in having moderate or greater TR, while a 10° decrease in APM angle at mid-systole was associated with an almost 2.5-fold increase in moderate or greater TR (P ≤ .01 for all). CONCLUSIONS: The tricuspid annulus in patients with HLHS with a Fontan circulation changes in shape significantly throughout the cardiac cycle but remains relatively planar. Increased change in septolateral diameter and decreased APM angle are strongly associated with the presence of TR. These findings may inform annuloplasty methods and subvalvular interventions in these complex patients.


Assuntos
Ecocardiografia Tridimensional , Técnica de Fontan , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico por imagem , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Músculos Papilares/diagnóstico por imagem , Valva Tricúspide/diagnóstico por imagem
2.
Catheter Cardiovasc Interv ; 93(3): E143-E152, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30444053

RESUMO

BACKGROUND: Pulmonary insufficiency is a consequence of transannular patch repair in Tetralogy of Fallot (ToF) leading to late morbidity and mortality. Transcatheter native outflow tract pulmonary valve replacement has become a reality. However, predicting a secure, atraumatic implantation of a catheter-based device remains a significant challenge due to the complex and dynamic nature of the right ventricular outflow tract (RVOT). We sought to quantify the differences in compression and volume for actual implants, and those predicted by pre-implant modeling. METHODS: We used custom software to interactively place virtual transcatheter pulmonary valves (TPVs) into RVOT models created from pre-implant and post Harmony valve implant CT scans of 5 ovine surgical models of TOF to quantify and visualize device volume and compression. RESULTS: Virtual device placement visually mimicked actual device placement and allowed for quantification of device volume and radius. On average, simulated proximal and distal device volumes and compression did not vary statistically throughout the cardiac cycle (P = 0.11) but assessment was limited by small sample size. In comparison to actual implants, there was no significant pairwise difference in the proximal third of the device (P > 0.80), but the simulated distal device volume was significantly underestimated relative to actual device implant volume (P = 0.06). CONCLUSIONS: This study demonstrates that pre-implant modeling which assumes a rigid vessel wall may not accurately predict the degree of distal RVOT expansion following actual device placement. We suggest the potential for virtual modeling of TPVR to be a useful adjunct to procedural planning, but further development is needed.


Assuntos
Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Tetralogia de Fallot/cirurgia , Animais , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Modelos Animais , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Carneiro Doméstico , Tomografia Computadorizada por Raios X , Resultado do Tratamento
3.
Pediatr Cardiol ; 39(3): 538-547, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29181795

RESUMO

Mastering the technical skills required to perform pediatric cardiac valve surgery is challenging in part due to limited opportunity for practice. Transformation of 3D echocardiographic (echo) images of congenitally abnormal heart valves to realistic physical models could allow patient-specific simulation of surgical valve repair. We compared materials, processes, and costs for 3D printing and molding of patient-specific models for visualization and surgical simulation of congenitally abnormal heart valves. Pediatric atrioventricular valves (mitral, tricuspid, and common atrioventricular valve) were modeled from transthoracic 3D echo images using semi-automated methods implemented as custom modules in 3D Slicer. Valve models were then both 3D printed in soft materials and molded in silicone using 3D printed "negative" molds. Using pre-defined assessment criteria, valve models were evaluated by congenital cardiac surgeons to determine suitability for simulation. Surgeon assessment indicated that the molded valves had superior material properties for the purposes of simulation compared to directly printed valves (p < 0.01). Patient-specific, 3D echo-derived molded valves are a step toward realistic simulation of complex valve repairs but require more time and labor to create than directly printed models. Patient-specific simulation of valve repair in children using such models may be useful for surgical training and simulation of complex congenital cases.


Assuntos
Ecocardiografia Tridimensional/métodos , Valva Mitral/diagnóstico por imagem , Modelos Anatômicos , Impressão Tridimensional , Valva Tricúspide/diagnóstico por imagem , Criança , Ecocardiografia Tridimensional/economia , Humanos , Estudos Retrospectivos , Treinamento por Simulação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...